Especially for centrifugal and progressive cavity pumps Two designs.
Two signatures.

Centrifugal pumps run fast and often reveal faults through their hydraulics. Progressive cavity pumps (also called progressing cavity pumps or eccentric screw pumps) run slowly: at 100 rpm, one revolution takes 0.6 s – stable condition indicators need long measurement windows.

Typical signatures by pump type

Typical signatures from vibration diagnostics – and how OtterFlow makes them visible.

Centrifugal pumps

Centrifugal pump with measurement pointSchematic side view of a centrifugal pump with drive and bearings, mechanical seal and impeller as well as the measurement point on the bearing housing Drive and bearingsMeasurement pointMechanical sealDischarge sideImpellerSuction side OtterFlow VIB-T 1 2 3 4 5 6
  • 1 Drive and bearings
  • 2 Measurement point · OtterFlow VIB-T
  • 3 Mechanical seal
  • 4 Discharge side
  • 5 Impeller
  • 6 Suction side
Example: centrifugal pump – schematic representation based on a common model, not a specific product series.

Vane pass frequency

If the component at number of vanes × rotational frequency rises, this can indicate clearance wear, clogging or operation far from the best efficiency point.

With OtterFlow

OtterFlow shows this component in the spectrum and as a trend.

Cavitation

A broadband rise in high-frequency acceleration is typical.

With OtterFlow

OtterFlow shows this rise as a trend.

Dry running and gas

The vibration pattern changes abruptly and the mechanical seal heats up quickly. The protective device designed for this purpose remains the decisive safeguard.

With OtterFlow

OtterFlow documents vibration and temperature as a supplement – this does not replace dry-run protection.

Progressive cavity pumps

Progressive cavity pump with measurement pointSchematic side view of a progressive cavity pump with geared motor, bearings, joints, rotor and stator as well as the measurement point on the bearing housing Drive and bearingsMeasurement pointSuction sideJoints and coupling rodRotor and statorDischarge side OtterFlow VIB-T 1 2 3 4 5 6
  • 1 Drive and bearings
  • 2 Measurement point · OtterFlow VIB-T
  • 3 Suction side
  • 4 Joints and coupling rod
  • 5 Rotor and stator
  • 6 Discharge side
Example: progressive cavity pump – schematic representation based on a common model, not a specific product series.

Speed

With OtterFlow

OtterFlow extends the measurement windows at low speed – optionally with a speed signal from the variable frequency drive or speed sensor.

Joints and coupling rod

Wear typically causes impacts synchronised with the rotational speed.

With OtterFlow

OtterFlow shows them as a trend using impulse indicators such as the crest factor.

Stator

Wear shows up mainly in process variables such as a declining flow rate.

With OtterFlow

With flow, pressure and speed values, OtterFlow compares operation with reference curves.

We clarify in the introductory call whether your measurements are sufficient for this.

Dry running

The stator elastomer heats up within a short time, the bearing housing only after a considerable delay. The protective device designed for this purpose remains the decisive safeguard.

With OtterFlow

OtterFlow documents temperature trends as a supplement – this does not replace dry-run protection.

Temperature

Temperature complements vibration as a rather late indicator, for example of lubrication problems, overload or cooling problems.

With OtterFlow

VIB-T measures the temperature with a Pt1000 sensor in the metal sensing head – not via the internal temperature of the sensor chip.

Notices from OtterFlow highlight anomalies; they are not a remote diagnosis – we assess the cause together with you. You decide what needs to be done.

OtterFlow does not intervene in control systems or protective devices and does not switch anything off.

Industries

Pumps handle water, wastewater, sludge and feedstock – often in continuous operation. If one of them stops, more than just the pump quickly comes to a standstill.

OtterFlow is made for operators and service partners of centrifugal and progressive cavity pumps – for example in biogas plants, in the water and wastewater sector and in industrial process plants.

  • Biogas plants
  • Water and wastewater sector
  • Industrial process plants

For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.

Typical operational questions

For example

  • Bearings or joints fail sooner than expected.
  • A centrifugal pump often runs far from its best efficiency point.
  • The flow rate of a progressive cavity pump is declining.
  • After an overhaul, the aim is to record how the pump runs in normal operation.
  • Calendar-based inspections come sometimes too early, sometimes too late.

You bring a specific operational question; we bring the measurement equipment and the time for the analysis.

Arrange an introductory call

Tell us in an introductory call of about 20 minutes which pump is on your mind. We clarify the process, installation, IT and terms – and decide together whether OtterFlow suits your plant.