Measuring principle

Pump vibration analysis What vibration and temperature reveal about your pump.

Typical signatures

Typical signatures from vibration diagnostics – and how OtterFlow makes them visible.

Scroll the graphic sideways

Frequency map of typical signaturesSchematic frequency map: on the left, rotational frequency and harmonics with the typical rotational frequencies of progressive cavity and centrifugal pumps as well as the vane pass frequency of centrifugal pumps; on the right, the kilohertz range with excited natural frequencies of bearing, housing and sensor mounting as well as cavitation; on the far right, ultrasound Rotational frequency and harmonics Kilohertz range Ultrasound Envelope: reveals the sequence of impacts Misalignment Unbalance:increased 1× Coupling Looseness Natural frequencies Cavitation Vane pass frequency(centrifugal pump) 0.5× 1× 1.5× 2× 3×–10× Frequency
  • 1× = rotational frequency of the pump
  • typical: progressive cavity pump 1.7–8.3 Hz · centrifugal pump 24–49 Hz
  • Vane pass frequency = number of vanes × rotational frequency; shown in the map at 6× as an example (impeller with six vanes).
  • Bearing defect frequencies: not integer multiples
Schematic representation based on a common model.

Mechanical faults

  • Unbalance: typically increased vibration at 1×, predominantly radial.

  • Misalignment: typically at 1× and 2× – angular misalignment mainly axial, parallel misalignment mainly radial.

  • Mechanical looseness: typically numerous harmonics, including half orders.

  • Coupling wear: typically a rising 2× component, often axial.

With OtterFlow

With a documented mounting orientation, three axes show axial and radial components separately – for example to narrow down misalignment together with you.

Bearings, lubrication, hydraulics

  • Rolling bearing damage: typically impacts that excite natural frequencies in the kilohertz range from an early stage – only weakly at low speed.

  • Lubrication: if high-frequency vibration and temperature rise together, this can indicate lubrication problems.

  • Cavitation: typically a broadband rise in high-frequency acceleration, mainly in centrifugal pumps.

    With OtterFlow

    OtterFlow shows this rise as a trend.

  • Vane pass frequency: if the component at number of vanes × rotational frequency rises in centrifugal pumps, this can indicate clearance wear, clogging or operation far from the best efficiency point.

    With OtterFlow

    OtterFlow shows this component in the spectrum and as a trend.

With OtterFlow

OtterFlow computes condition indicators such as high-frequency acceleration, envelope, kurtosis and crest factor and shows them together with the temperature.

Envelope and order spectra show bearing-specific defect frequencies – calculated from bearing data and speed.

Progressive cavity pumps: joints and stator

  • Joints and coupling rod

    Wear typically causes impacts synchronised with the rotational speed.

    With OtterFlow

    OtterFlow shows them as a trend using impulse indicators such as the crest factor.

  • Stator

    Wear shows up mainly in process variables such as a declining flow rate.

    With OtterFlow

    With flow, pressure and speed values, OtterFlow compares operation with reference curves.

    We clarify in the introductory call whether your measurements are sufficient for this.

Dry running

  • Centrifugal pump: dry running and gas

    The vibration pattern changes abruptly and the mechanical seal heats up quickly. The protective device designed for this purpose remains the decisive safeguard.

    With OtterFlow

    OtterFlow documents vibration and temperature as a supplement – this does not replace dry-run protection.

  • Progressive cavity pump

    The stator elastomer heats up within a short time, the bearing housing only after a considerable delay. The protective device designed for this purpose remains the decisive safeguard.

    With OtterFlow

    OtterFlow documents temperature trends as a supplement – this does not replace dry-run protection.

Notices from OtterFlow highlight anomalies; they are not a remote diagnosis – we assess the cause together with you. You decide what needs to be done.

Rotational frequency, harmonics and measurement windows

1× = rotational frequency of the pump. Typical: progressive cavity pump 1.7–8.3 Hz · centrifugal pump 24–49 Hz.

1.7–8.3 Hz corresponds to 100–500 rpm, 24–49 Hz to around 1,440–2,940 rpm.

In the frequency map, the harmonics of the rotational frequency appear as 0.5× · 1× · 1.5× · 2× · 3×–10×.

Measurement windows

Centrifugal pumps run fast and often reveal faults through their hydraulics. Progressive cavity pumps run slowly: at 100 rpm, one revolution takes 0.6 s – stable indicators need long measurement windows.

The longer the measurement window, the finer the frequency resolution – roughly 1 divided by the measurement time: 4 s gives around 0.25 Hz, 10 s around 0.1 Hz. That is why slow-running pumps need long measurement windows.

With OtterFlow

OtterFlow extends the measurement windows at low speed – optionally with a speed signal from the variable frequency drive or speed sensor.

Indicators explained

Vibration velocity

How strongly the measurement point vibrates – per axis; meaningful above all for mechanical causes such as unbalance or misalignment.

High-frequency acceleration

The fast components of the vibration – this is where short impacts, for example from rolling bearings, and broadband excitation, as with cavitation, become visible.

Envelope

Reveals the sequence of impacts – that is, how regularly short impacts recur, for example with rolling bearing damage.

Crest factor

Ratio of peak value to RMS value – rises when individual impacts stand out from the signal.

Kurtosis

Measure of the impulsiveness of the signal – responds to short, strong impulses.

With OtterFlow

OtterFlow tracks indicators such as vibration velocity per axis against the approved baseline and highlights deviations.

Temperature

Temperature complements vibration as a rather late indicator, for example of lubrication problems, overload or cooling problems.

With OtterFlow

VIB-T measures the temperature with a Pt1000 sensor in the metal sensing head – not via the internal temperature of the sensor chip.

Limit values and baseline

Limit values alone are not enough.

For centrifugal pumps, standards give guideline values for vibration; for progressive cavity pumps, there are no generally applicable ones – by design, their rotor runs eccentrically. In both cases, damage often shows up as a change before a limit value is reached.

What matters is the change. That is why we make your own pump the benchmark.

Arrange an introductory call

Tell us in an introductory call of about 20 minutes which pump is on your mind. We clarify the process, installation, IT and terms – and decide together whether OtterFlow suits your plant.

+49 4221 964 99 99

info@otterflow.eu

Product preview with synthetic sample data