Our approach

Not by the table.
By your pump.
Our approach to predictive maintenance for pumps

Condition monitoring as the basis for predictive maintenance of your pumps: OtterFlow evaluates against a jointly approved baseline of your pump – not against generic table values.

Your day-to-day operations

Great responsibility.
Little insight.

Pumps handle water, wastewater, sludge and feedstock – often in continuous operation. If one of them stops, more than just the pump quickly comes to a standstill.

What happens inside a pump usually remains hidden: bearings wear, impellers clog up, stators wear out. This often does not become visible until the flow rate declines – or the pump stops.

Calendar-based inspections tie up staff – and come sometimes too early, sometimes too late. Over the life cycle of a pump, the costs of unplanned downtime can reach the level of its energy and spare-parts costs.1

OtterFlow is made for operators and service partners of centrifugal and progressive cavity pumps – for example in biogas plants, in the water and wastewater sector and in industrial process plants.

For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.

Limit values alone are not enough.

For centrifugal pumps, standards give guideline values for vibration; for progressive cavity pumps, there are no generally applicable ones – by design, their rotor runs eccentrically. In both cases, damage often shows up as a change before a limit value is reached.

What matters is the change. That is why we make your own pump the benchmark.

Progressive cavity pump with measurement pointSchematic side view of a progressive cavity pump with geared motor, bearings, joints, rotor and stator as well as the measurement point on the bearing housing Drive and bearingsMeasurement pointSuction sideJoints and coupling rodRotor and statorDischarge side OtterFlow VIB-T 1 2 3 4 5 6
  • 1 Drive and bearings
  • 2 Measurement point · OtterFlow VIB-T
  • 3 Suction side
  • 4 Joints and coupling rod
  • 5 Rotor and stator
  • 6 Discharge side
Example: progressive cavity pump – schematic representation based on a common model, not a specific product series.

Footnotes

  1. Hydraulic Institute, Europump, U.S. Department of Energy: Pump Life Cycle Costs – A Guide to LCC Analysis for Pumping Systems, Executive Summary, 2001. Back to text

In three steps

Baseline instead of table values

Indicator against the approved baselineIllustration: an indicator initially stays within the band of the approved baseline, then rises and leaves the band; at that point, a notice for joint review appears Indicator Time Approved baseline 01 Record 02 Change 03 Notice for review
  • 01 Record
  • 02 Change
  • 03 Notice for review
  • Band: approved baseline
Schematic representation – not measured data.
  1. 01

    Record the baseline

    After OtterFlow has been commissioned, ideally after an overhaul, we record how your pump behaves in normal operation – if required for each operating condition, for example each speed range. We approve this baseline together with you – traceable rather than automatically learned.

  2. 02

    See changes

    OtterFlow tracks condition indicators such as vibration velocity per axis against this baseline and highlights deviations.

  3. 03

    Review together

    Notices from OtterFlow highlight anomalies; they are not a remote diagnosis – we assess the cause together with you. You decide what needs to be done.

Our goal: fewer unplanned stoppages and more targeted inspections. How much of this can be achieved at your plant is something we measure together – month by month.

System overview

From the pump
to the cloud.

  1. OtterFlow VIB-⁠T

    Sensor for vibration and temperature

  2. OtterFlow Pump Unit

    Combines up to four VIB-T sensors per pump, evaluates data on site and buffers data during connection outages.

  3. OtterFlow Cloud

    Your workspace at otterflow.cloud

OtterFlow does not intervene in control systems or protective devices and does not switch anything off.

System overview – schematic representation.

Operation in the cloud or on your own network, CSV export and an openly documented API.

What OtterFlow does not do

OtterFlow provides supplementary monitoring: it does not intervene in control systems or protective devices, does not replace dry-run or machine protection and is intended for use outside hazardous areas.

For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.

Notices from OtterFlow support maintenance; we do not promise failure prediction or specific savings.

One shared picture for operations, maintenance and service.

For operators

  • Assessment against a jointly approved baseline of your pump – not against generic table values.
  • All pumps, measured values and notices in one place – in the browser, at your desk and on the move, without installing an app.
  • You bring a specific operational question; we bring the measurement equipment and the time for the analysis.

For service partners

  • A dedicated workspace for your company, with user access and roles for colleagues and service partners.
  • Raw-data windows, envelope and order spectra with bearing-specific defect frequencies for expert assessment.
  • With a documented mounting orientation, three axes show axial and radial components separately – for example to narrow down misalignment together with you.

Operator or service partner: you have a direct line to us in Delmenhorst – from installation to analysis.

Arrange an introductory call

Tell us in an introductory call of about 20 minutes which pump is on your mind. We clarify the process, installation, IT and terms – and decide together whether OtterFlow suits your plant.

+49 4221 964 99 99

info@otterflow.eu

Product preview with synthetic sample data