Products

From the pump
to the cloud.
Pump monitoring with OtterFlow VIB-⁠T, Pump Unit and Cloud

New: sensor and cloud from a single source.

System overview

One system of three building blocks

  1. OtterFlow VIB-⁠T

    Sensor for vibration and temperature

  2. OtterFlow Pump Unit

    Combines up to four VIB-T sensors per pump, evaluates data on site and buffers data during connection outages.

  3. OtterFlow Cloud

    Your workspace at otterflow.cloud

OtterFlow does not intervene in control systems or protective devices and does not switch anything off.

System overview – schematic representation.

Sensor, device and cloud

Design visualisation of the OtterFlow VIB-T sensor in an oblique view from above, with cable gland and cable

OtterFlow VIB-⁠T

Sensor for vibration and temperature

OtterFlow VIB-T – our own sensor for vibration in three axes and temperature, developed in Delmenhorst for use on pumps.

  • Three axes simultaneously: axial and radial vibration at one measurement point.
  • VIB-T sits directly on the bearing housing and records all three axes simultaneously at a sampling rate of 16 kHz. This keeps even short impacts from rolling bearings visible.
  • Mounting without drilling: adhesive mounting base for flat and cylindrically curved surfaces from approx. Ø 60 mm.

For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.

Diagram of the OtterFlow Pump UnitSchematic representation of the OtterFlow Pump Unit with up to four connected VIB-T sensors and its connection via LAN, WLAN or LTE to OtterFlow Cloud or to your own network OtterFlow Pump Unit OtterFlow Cloud up to four VIB-T sensors per pump one cable each for power and data LAN · WLAN · LTE or operation on your own network Diagram of the OtterFlow Pump UnitSchematic representation of the OtterFlow Pump Unit with up to four connected VIB-T sensors and its connection via LAN, WLAN or LTE to OtterFlow Cloud or to your own network OtterFlow Pump Unit OtterFlow Cloud up to four VIB-T sensors per pump one cable each for power and data LAN · WLAN · LTE or operation on your own network
OtterFlow Pump Unit – schematic representation.

OtterFlow Pump Unit

Device at the pump

The OtterFlow Pump Unit is the device at the pump: it combines up to four VIB-T sensors per pump, evaluates data on site and buffers data during connection outages.

  • Connectivity: LAN, WLAN or LTE
  • During connection outages: local buffering and later transmission within the storage capacity
  • Measurement data is transmitted via MQTT over TLS with mutual certificate authentication.
Overview in OtterFlow Cloud with plants and anomalies (sample data, screenshot: German version)
OtterFlow Cloud – sample view with sample data (screenshot: German version).

OtterFlow Cloud

Measured values, trends and notices

All pumps, measured values and notices in one place – in the browser, at your desk and on the move, without installing an app.

  • Overview and trends: condition indicators and temperature for each measurement point – from one-second values to long-term trends.
  • Detailed analysis: raw-data windows, envelope and order spectra with bearing-specific defect frequencies for expert assessment.
  • Your data, your choice: operation in the cloud or on your own network, CSV export and an openly documented API.

Notices indicate anomalies, not a confirmed defect.

Sensors and measured variables

Vibration and temperature at the measurement point.
Speed, pressure and flow from your plant.

OtterFlow VIB-T records vibration and temperature directly at the measurement point. Optionally, OtterFlow also uses speed, pressure and flow values – the speed from the variable frequency drive or speed sensor. How these values are transferred is agreed individually.

Measured variables and their sources
Measured variable Source What OtterFlow uses it for
Vibration in three axes OtterFlow VIB-T, directly on the bearing housing: 3-axis MEMS accelerometer, 16 kHz sampling rate per axis indicators directly at the measurement point – vibration velocity, high-frequency acceleration, envelope, crest factor and kurtosis; trend against the approved baseline
Temperature OtterFlow VIB-T: Pt1000 temperature sensor in the metal sensing head – not the internal temperature of the sensor chip temperature for each measurement point as a trend, together with the vibration
Speed from your plant, optionally: speed signal from the variable frequency drive or speed sensor longer measurement windows at low speed, baseline for each speed range, order spectra and bearing-specific defect frequencies
Pressure measured values from your plant, optionally in addition – the transfer is agreed individually comparison of operation with reference curves – together with flow and speed
Flow measured values from your plant, optionally in addition – the transfer is agreed individually comparison of operation with reference curves – together with pressure and speed

We clarify in the introductory call whether your measurements are sufficient for this.

Up to four VIB-T sensors per pump, connected to the OtterFlow Pump Unit.

Pump card in OtterFlow Cloud with temperature, vibration and speed (sample data, screenshot: German version)
OtterFlow Cloud – sample view with sample data (screenshot: German version).

Arrange an introductory call

Tell us in an introductory call of about 20 minutes which pump is on your mind. We clarify the process, installation, IT and terms – and decide together whether OtterFlow suits your plant.

+49 4221 964 99 99

info@otterflow.eu

Product preview with synthetic sample data