OtterFlow VIB-T Vibration and temperature.
Measured at one point.
OtterFlow VIB-T – our own sensor for vibration in three axes and temperature, developed in Delmenhorst for use on pumps.
3-axis MEMS accelerometer, Pt1000 temperature sensor, metal housing made of aluminium, approx. Ø 48 mm, height approx. 44 mm. For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.
System overview
From the pump
to the cloud.
-
OtterFlow VIB-T
Sensor for vibration and temperature
One cable for power and data – no battery and no radio at the sensor
-
OtterFlow Pump Unit
Combines up to four VIB-T sensors per pump, evaluates data on site and buffers data during connection outages.
LAN · WLAN · LTE
-
OtterFlow Cloud
Your workspace at otterflow.cloud
OtterFlow does not intervene in control systems or protective devices and does not switch anything off.
Measured variables and indicators
Each direction separately
Three axes simultaneously: axial and radial vibration at one measurement point.
Temperature at the mounting location
Pt1000 temperature sensor in the metal sensing head – not the internal temperature of the sensor chip.
Indicators on site
Condition indicators directly at the measurement point – vibration velocity, high-frequency acceleration, envelope, crest factor and kurtosis.
Envelope: reveals the sequence of impacts · Crest factor: peak value to RMS value · Kurtosis: impulsiveness of the signal
Bonding instead of drilling
Mounting without drilling: adhesive mounting base for flat and cylindrically curved surfaces from approx. Ø 60 mm.
Measured where it matters.
VIB-T sits directly on the bearing housing and records all three axes simultaneously at a sampling rate of 16 kHz. This keeps even short impacts from rolling bearings visible.
Mounting without drilling
Mounting takes place during an agreed shutdown. Scope, installation, support and terms are agreed individually.
One cable for power and data – no battery and no radio at the sensor.
The connection to the OtterFlow Pump Unit has its own pin assignment – no IO-Link and no 24 V connection.
Cable: permanently attached, shielded, approx. 2 m.
Technical data
Measurement
- Measured variables
- vibration (acceleration) in three axes simultaneously · temperature at the measurement point
- Sensor principle
- 3-axis MEMS accelerometer
- Sampling rate
- 16 kHz per axis, all three axes simultaneously
- Axes
- axial and radial at one measurement point; assignment via the documented mounting orientation
- Temperature sensor
- Pt1000 in the metal sensing head – not the internal temperature of the sensor chip
- Indicators
- vibration velocity, high-frequency acceleration, envelope, crest factor, kurtosis; plus temperature
Mounting and connection
- Mounting location
- directly on the bearing housing
- Mounting
- without drilling: adhesive mounting base for flat and cylindrically curved surfaces from approx. Ø 60 mm
- Connection
- one cable to the OtterFlow Pump Unit for power and data; own pin assignment, no IO-Link and no 24 V connection
- Cable
- permanently attached, shielded, approx. 2 m
- Power
- no battery and no radio at the sensor
Housing and use
- Housing
- metal housing made of aluminium, CNC-machined
- Dimensions
- approx. Ø 48 mm, height approx. 44 mm
- Area of use
- For use outside potentially explosive atmospheres (non-hazardous area). No Ex certification.
- System
- up to four VIB-T sensors per pump on one OtterFlow Pump Unit
Illustrations may differ. Subject to technical changes; errors excepted.